rascsi(1) General Commands Manual rascsi(1)
|
||||
|
||||
NAME
|
||||
rasctl - Sends management commands to the rascsi process
|
||||
|
||||
SYNOPSIS
|
||||
rasctl -l | -i ID [-u UNIT] [-c CMD] [-t TYPE] [-f FILE]
|
||||
|
||||
DESCRIPTION
|
||||
rasctl Sends commands to the rascsi process to make configuration adjustments at runtime or to check the sta‐
|
||||
tus of the devices.
|
||||
|
||||
Either the -i or -l option should be specified at one time. Not both.
|
||||
|
||||
You do NOT need root privileges to use rasctl.
|
||||
|
||||
Note: The command and type arguments are case insensitive. Only the first letter of the command/type are
|
||||
evaluated by the tool.
|
||||
|
||||
OPTIONS
|
||||
-l List all of the devices that are currently being emulated by RaSCSI, as well as their current status.
|
||||
|
||||
-i ID ID is the SCSI ID that you want to control. (0-7)
|
||||
|
||||
-u UNIT
|
||||
Unit number (0 or 1). This will default to 0. This option is only used when there are multiple SCSI
|
||||
devices on a shared SCSI controller. (This is not common)
|
||||
|
||||
-c CMD Command is the operation being requested. options are:
|
||||
attach: attach disk
|
||||
detach: detach disk
|
||||
insert: insert media (Magneto-Optical and CD only)
|
||||
eject: eject media (Magneto-Optical and CD only)
|
||||
protect: Write protect the media (Magneto-Optical only)
|
||||
|
||||
When the command is omited, rasctl will default to the 'attach' command
|
||||
|
||||
-t TYPE
|
||||
Specifies the type of disk. If this disagrees with the file extension of the specified image, the TYPE
|
||||
argument is ignored. Available drive types are:
|
||||
hd: Hard disk (SCSI or SASI)
|
||||
mo: Magneto-Optical disk)
|
||||
cd: CD-ROM
|
||||
bridge: Bridge device (This is only applicable to the Sharp X68000)
|
||||
|
||||
-f FILE
|
||||
Path to the disk image file. See the rascsi(1) man page for allowable file types.
|
||||
|
||||
EXAMPLES
|
||||
Show a listing of all of the SCSI devices and their current status
|
||||
rasctl -l
|
||||
|
||||
Example output:
|
||||
+----+----+------+-------------------------------------
|
||||
| ID | UN | TYPE | DEVICE STATUS
|
||||
+----+----+------+-------------------------------------
|
||||
| 0 | 1 | SCHD | /home/pi/harddisk.hda
|
||||
+----+----+------+-------------------------------------
|
||||
|
||||
Request the RaSCSI process to attach a disk (assumed) to SCSI ID 0 with the contents of the file system image
|
||||
"HDIIMAGE0.HDS".
|
||||
rasctl -i 0 -f HDIIMAGE0.HDS
|
||||
|
||||
SEE ALSO
|
||||
rascsi(1)
|
||||
|
||||
Full documentation is available at: <https://www.github.com/akuker/RASCSI/wiki/>
|
||||
|
||||